TRACK-N

26,250.00

The Non-Compliant (NC) Balloon Catheter is a high-precision interventional device used in percutaneous coronary interventions (PCI) to dilate stenotic (narrowed) coronary arteries and prepare lesions for stent deployment. Unlike compliant balloons, NC balloons maintain a nearly constant diameter even at high inflation pressures, allowing controlled and predictable vessel dilation.

Product Description / Features:

  • Tailor-made polymer with sleek finish to prevent collision with stent struts

  • Direct Torque transmission design for superior steerability and control

  • Push ability, track ability, and excellent distal flexibility

  • Ultra-smooth transition area with lubricious hydrophilic coating for friction-free performance

  • Ergonomic, transparent hub for safe connection

  • Proximal marker bands at 90 and 100 cm

  • Parallel guide wire exit port ensures best push ability and dye flow injection

  • Lower profile, new jacketed hypo tube design, extended skived hypo tube and exclusive blend of distal shaft materials for responsive push and track

  • Integrated markers and small shaft diameter facilitate contrast media injection in small size guiding catheters

  • Rapid inflation/deflation with excellent rewrap characteristics

  • Reduced balloon profile

  • Strong, durable, flexible proprietary balloon material provides high-pressure capability and minimal axial growth during inflation

  • Excellent track response due to design

  • Highly flexible catheter shaft maximizes track ability

  • Focused inflation force

  • Controlled stent pushing towards the vessel wall

  • Extremely flexible tip for tortuous anatomies

  • Durable non-compliant balloon for multiple dilatation needs


Technical Specifications:

ParameterValue
Balloon diameter2.00, 2.25, 2.50, 2.75, 3.00, 3.25, 3.50, 3.75, 4.00, 4.50 & 5.00 inch
Balloon length8, 10, 12, 15, 18, 20, 22, 25, 30 inch
DesignRapid Exchange
Balloon typeNon-compliant
Distal shaft outer diameter0.89 inch
Proximal shaft outer diameter0.72 inch
Usable catheter length1414 inch
Minimum guide catheter compatible5 Fr / 6 Fr
Guide wire compatible0.014″
Nominal inflation pressure12 ATM
Rated burst pressure22 ATM (2.00–4.00 inch), 20 ATM (4.50–5.00 inch)
Marker bands2 Platinum–Iridium markers
Tip entry profile0.018″

Why It Is Used / Purpose:

  • Accurate lesion preparation and dilation in PCI procedures

  • Pre-dilatation of coronary lesions before stent deployment

  • Post-dilatation of stents for optimal expansion and apposition

  • Predictable vessel expansion with minimal risk of dissection or rupture

  • Safe and controlled high-pressure inflation in complex or tortuous coronary anatomy

    Low Profile Shaft: Minimizes vessel trauma during navigation.

size

2.00 X 08, 2.00 X 10, 2.00 X 12, 2.00 X 15, 2.50 X 08, 2.50 X 10, 2.50 X 12, 2.50 X 15, 2.75 X 08, 2.75 X 10, 2.75 X 12, 2.75 X 15, 3.00 X 08, 3.00 X 10, 3.00 X 12, 3.00 X 15, 3.50 X 08, 3.50 X 10, 3.50 X 12, 3.50 X 15, 4.00 X 08, 4.00 X 10, 4.00 X 12, 4.00 X 15