TRACK-S

23,437.50

Semi-Compliant PTCA Balloon Catheters are specialized medical devices used in percutaneous transluminal coronary angioplasty (PTCA) procedures. These catheters are primarily designed for predilatation of coronary arteries, lesion preparation, and facilitating stent delivery.

Unlike non-compliant balloons, semi-compliant balloons are designed to slightly expand beyond their nominal diameter when higher pressure is applied. This controlled adaptability makes them particularly useful in cases where the artery has irregular or calcified lesions. They balance flexibility and precision, ensuring that the vessel is adequately prepared without the risk of uncontrolled vessel trauma.


🌟 Why Semi-Compliant PTCA Balloons Are Important:

  • Flexibility: The balloon conforms slightly to vessel anatomy, making it easier to cross tortuous or curved vessels.

  • Adaptability: Useful in initial lesion preparation as they can expand beyond nominal size under higher pressures.

  • Safety: Reduces the risk of vessel rupture compared to over-dilating with non-compliant balloons.

  • Supportive Role: Ideal for stent placement since they can open up narrowed vessels adequately before deploying the stent.


📌 Common Clinical Uses:

  • Dilatation of de novo coronary lesions

  • Preparing calcified or fibrotic lesions before stent placement

  • Post-stent optimization when small adjustments are needed

  • Navigating complex, tortuous coronary anatomies due to trackability

  • Lesion preparation in elective PCI and primary angioplasty


⚡ Advanced Features:

  • Ultra-thin balloon wall for low crossing profile and smooth lesion entry

  • Radiopaque markers for precise balloon positioning under fluoroscopy

  • Rapid inflation/deflation system reduces procedure time and patient risk

  • Semi-compliant material allows diameter growth up to 10–15% at high pressure

  • Shaft design ensures pushability and torque control

  • Rated Burst Pressure (RBP) up to 20 atm for challenging lesions


📏 Technical Specifications (Expanded):

  • Balloon Diameter Range: 1.0 mm to 5.0 mm

  • Common Sizes: 1.25, 1.50, 1.75, 2.00, 2.25, 2.50, 2.75, 3.00, 3.25, 3.50, 3.75, 4.00 mm

  • Balloon Lengths: 6 mm, 8 mm, 10 mm, 12 mm, 15 mm, 20 mm, 25 mm, 30 mm

  • Balloon Compliance: Semi-compliant (controlled expansion under pressure)

  • Nominal Pressure (NP): 6–8 atm

  • Rated Burst Pressure (RBP): Up to 20 atm

  • Usable Catheter Length: 144 cm

  • Guidewire Compatibility: 0.014”

  • Sheath Compatibility: 5F / 6F introducer sheath

  • Tip Entry Profile: 0.016” (for smooth lesion entry)

  • Marker Bands: 2 Platinum–Iridium markers

size

1.25 X 8, 1.25 X 10, 1.25 X 12, 1.25 X 15
1.50 X 8, 1.50 X 10, 1.50 X 12, 1.50 X 15
2.00 X 8, 2.00 X 10, 2.00 X 12, 2.00 X 15
2.50 X 8, 2.50 X 10, 2.50 X 12, 2.50 X 15